Please wait while the page is being loaded Skip this advertisement >
Friday | 29 August, 2008
ARN
RAID 6 covers more bases
Double parity provides a higher level of fault tolerance by protecting data on two drives in the event of a failure
Charles Eischen (Network World) 11 April, 2007 12:20:11

Related Stories
  • +

    UTM firewalls: Ready for the enterprise 03 September, 2007 08:50:17

    However, deciding whether and where to deploy UTM appliances in a large enterprise is a more complicated and difficult decision.
    IT managers at small and midsize businesses like unified threat management appliances - firewalls that layer on antimalware protection, content filtering, antispam and intrusion prevention - because deploying a single, multi-function device reduces costs and simplifies configuration.
ARN Directory | Distributors relevant to this article
Additional Resources
ARN Library

Newsletter Subscription

Sign up for our ARN newsletters!
The premier provider of daily news to the IT channel, covering business, technology, products, and services.
RSS Feeds

RAID technology -- Redundant Array of Independent Disks -- lets you establish varying degrees of data protection depending on the particular requirements of a given application. RAID levels 0, 1, 5 and 10 have been the most widely used, with RAID 5 (rotational parity) reigning supreme for fault tolerance because it allows data on a failed drive to be rebuilt without losing accessibility to stored information. RAID 6 (double parity) provides a higher level of fault tolerance by protecting data on two drives in the event of a failure.

In a RAID 5 array data is striped across all drives and parity information is distributed and stored across all the disks. If a drive fails the surviving array operates in degraded mode until the failed drive is replaced and its data is rebuilt from the parity information. But all data will be lost in the event of a second drive failure during a rebuild or a latent media defect that causes a read error during the rebuild. Today's increased hard disk capacities are causing longer rebuild times, which increases the likelihood that a second drive will fail during rebuild.

RAID 6 eliminates that risk. In a RAID 6-enabled system a second set of parity is calculated, written and distributed across all the drives. This second parity calculation provides significantly more fault tolerance because two drives can fail without resulting in data loss (see graphic).

But the additional calculations required with RAID 6 adversely affect write performance. Performance benchmarks show a RAID controller can suffer more than a 30 percent drop in overall write performance compared with a RAID 5 implementation. RAID 5 and RAID 6 read performance are comparable.

RAID suppliers implement their designs differently, so it is important to find controllers that minimize the RAID 6 write penalty. Look for controllers that make double parity calculations simultaneously and that use dedicated, silicon-based stripe handlers to reduce the write penalty radically.

Capacity considerations

RAID 5 implementations require a minimum of three drives and have the storage capacity of N-1 drives because the equivalent capacity of one drive is exclusively dedicated to holding parity data. For example in a four-drive, 200GB-per-drive array, the available storage capacity is 600GB out of a total of 800GB.

RAID 6 implementations require a minimum of four drives and have the storage capacity of N-2 drives because the equivalent capacity of two drives is exclusively dedicated to holding parity data. The available storage capacity is 400GB of 800GB.

While RAID 6 can be used with as few as four drives, RAID 10 is a higher-performing configuration that tolerates most two-drive failures in a four-drive array. RAID 10 mirrors and stripes data to maximize redundancy and performance. A RAID mirror does not require a read-modify-write operation as RAID 5 and RAID 6 arrays do. RAID 6 is recommended over RAID 10 for implementations with more than four drives.

In summary, RAID 6 provides higher levels of data protection, data availability and fault tolerance than RAID 5, but it comes at a cost. RAID 6 requires the equivalent capacity of two drives in the array to be dedicated to storing parity information, and most RAID 6 systems carry a heavy write-performance burden because of the additional parity calculation and the additional memory interruptions. Simultaneous parity calculations can mitigate these performance impediments.

Eischen is senior marketing manager for AMCC's storage division. He can be reached at ceischen@amcc.com.

ARN Directory | Distributors relevant to this article
Market Place

ARN Member Login

 
Panel Sessions
  • ARN Panel Sessions: Day 3

    The last of our panel sessions recorded live at CeBIT 2008. Today, the topic is storage. Data is growing at an enormous rate, so what does the future hold?

Play
ARN news
  • IFA: LG's newest TV includes Bluetooth

    Bluetooth will be installed in models in LG's PG7000-series plasma sets and LG7000-series LCD sets, which are due on sale across Europe before the end of September.

Play
Channel Watch
  • Brian's bloopers

    It takes a long time to produce an episode of Channel Watch. Maybe you'll understand why after watching this...

Play
Business Continuity & Disaster Recovery Zone

When an IT disaster occurs, how handy it would be to push a button and start again as if nothing had happened.
Discover and learn more about CA XOSoft today.
ARN Vendor Directory
ARN Library

Dimension Data, La Trobe University and Windows Server 2008 partner to improve compliance

La Trobe University partnered with Dimension Data to deploy Windows Server 2008 and Network Access Protection technology to improve their existing network security solution.

Sponsored Links