- +
SMB Servers 25 May, 2007 13:40:35
SMB Servers - +
UTM firewalls: Ready for the enterprise 03 September, 2007 08:50:17
However, deciding whether and where to deploy UTM appliances in a large enterprise is a more complicated and difficult decision.IT managers at small and midsize businesses like unified threat management appliances - firewalls that layer on antimalware protection, content filtering, antispam and intrusion prevention - because deploying a single, multi-function device reduces costs and simplifies configuration.
Click here for case studies, whitepapers and other useful vendor content Australian water treatment company uses four GFI products to protect its network
Dimension Data, La Trobe University and Windows Server 2008 partner to improve compliance
WebCentral boosts Security and Reliability with Windows Server 2008
Bankstown Council streamlines their IT with Microsoft® Windows Server® 2008
Dataract increases e5 Workflow performance with Microsoft® Windows Server® 2008
V/Line and Oakton use Microsoft SQL Server 2008 to develop an Executive HR Dashboard
Microsoft® takes legal action against software pirates
NAB works with Avanade® to leverage Microsoft® Windows Server® 2008 for its branch offices
Newsletter Subscription
RAID technology -- Redundant Array of Independent Disks -- lets you establish varying degrees of data protection depending on the particular requirements of a given application. RAID levels 0, 1, 5 and 10 have been the most widely used, with RAID 5 (rotational parity) reigning supreme for fault tolerance because it allows data on a failed drive to be rebuilt without losing accessibility to stored information. RAID 6 (double parity) provides a higher level of fault tolerance by protecting data on two drives in the event of a failure.
In a RAID 5 array data is striped across all drives and parity information is distributed and stored across all the disks. If a drive fails the surviving array operates in degraded mode until the failed drive is replaced and its data is rebuilt from the parity information. But all data will be lost in the event of a second drive failure during a rebuild or a latent media defect that causes a read error during the rebuild. Today's increased hard disk capacities are causing longer rebuild times, which increases the likelihood that a second drive will fail during rebuild.
RAID 6 eliminates that risk. In a RAID 6-enabled system a second set of parity is calculated, written and distributed across all the drives. This second parity calculation provides significantly more fault tolerance because two drives can fail without resulting in data loss (see graphic).
But the additional calculations required with RAID 6 adversely affect write performance. Performance benchmarks show a RAID controller can suffer more than a 30 percent drop in overall write performance compared with a RAID 5 implementation. RAID 5 and RAID 6 read performance are comparable.
RAID suppliers implement their designs differently, so it is important to find controllers that minimize the RAID 6 write penalty. Look for controllers that make double parity calculations simultaneously and that use dedicated, silicon-based stripe handlers to reduce the write penalty radically.
Capacity considerations
RAID 5 implementations require a minimum of three drives and have the storage capacity of N-1 drives because the equivalent capacity of one drive is exclusively dedicated to holding parity data. For example in a four-drive, 200GB-per-drive array, the available storage capacity is 600GB out of a total of 800GB.
RAID 6 implementations require a minimum of four drives and have the storage capacity of N-2 drives because the equivalent capacity of two drives is exclusively dedicated to holding parity data. The available storage capacity is 400GB of 800GB.
While RAID 6 can be used with as few as four drives, RAID 10 is a higher-performing configuration that tolerates most two-drive failures in a four-drive array. RAID 10 mirrors and stripes data to maximize redundancy and performance. A RAID mirror does not require a read-modify-write operation as RAID 5 and RAID 6 arrays do. RAID 6 is recommended over RAID 10 for implementations with more than four drives.
In summary, RAID 6 provides higher levels of data protection, data availability and fault tolerance than RAID 5, but it comes at a cost. RAID 6 requires the equivalent capacity of two drives in the array to be dedicated to storing parity information, and most RAID 6 systems carry a heavy write-performance burden because of the additional parity calculation and the additional memory interruptions. Simultaneous parity calculations can mitigate these performance impediments.
Eischen is senior marketing manager for AMCC's storage division. He can be reached at ceischen@amcc.com.
ARN Member Login
When an IT disaster occurs, how handy it would be to push a button and start again as if nothing had happened.
Discover and learn more about CA XOSoft today.
Satyam’s Q1 revenue up by 43% and Net Profit by 45% YoY; revises revenue and EPS guidance upwards for FY09 18 July, 2008 16:58:00
Informatica Reports Record Second Quarter Results 18 July, 2008 13:01:00
Tumbleweed Releases MailGate 3.6 18 July, 2008 10:01:00
Convergys to Acquire Intervoice, Enhancing Leadership in Relationship Management 17 July, 2008 14:41:00
Borland Management Solutions Put the "M" in Application Lifecycle Management 17 July, 2008 13:43:00
Dataract increases e5 Workflow performance with Microsoft® Windows Server® 2008
Since upgrading to Windows Server 2008 from Windows Server 2003, Dataract have made visible improvements in their workflow calculations and image presentation performance.












